Installation Guide

BioShieldUV® Classic (S) Series Complete Installation Guide

Models covered: BioS 18W Classic | BioS 36W Classic | BioS 72W Classic

20
min Install Time
8,000
Hours Lamp Life
253.7
nm UV-C Wavelength

Before You Begin: HVAC models must be installed by a licensed HVAC technician or electrical contractor. Installation by anyone other than a qualified professional voids the warranty. All installations must comply with applicable national and local building codes. Read all safety warnings in full before handling any components.

Suitable for Air-Handling Use Dry Locations Only ETL Listed (Certification Pending)

Quick Start options

Follow Safety Precautions closely before beginning installation.

Need help with your BioShield UV unit?

Find a certified installer in our professional directory.

Contact Us

Check Which Model You’ve Purchased

BioS 18W Classic
BioS 18W Classic
BioS 36W Classic
BioS 36W Classic
BioS 72W Classic
BioS 72W Classic

If You Ordered The Wrong Model, Please Contact Us To Exchange

Text or call (US & Canada) : +1 (307) 364 0340 Email : support@bioshielduv.com

Safety Warnings

Follow all safety and building codes. Read every warning below before installing, adjusting, or servicing the unit. These warnings apply to all models and all installation environments.

Safety overview

Installation Safety

Read the manual carefully before attempting to install the unit. Improper installation, adjustment, alteration, service, or maintenance can result in fire or electrical shock and create a risk of personal injury or property damage. Consult a licensed electrician or contractor for assistance during installation.

Lamp Handling

Handle the UV lamp with gloves at all times. Oils from bare hands reduce UV output and cannot be reversed by cleaning.

If the lamp glass is touched without gloves, wipe the affected area with isopropyl alcohol before powering the unit on.

Eye Safety

Never expose eyes directly to UV light. Looking at the lamp can cause eye damage.

Wear safety glasses during installation and any maintenance work.

Electrical Safety

Turn off the main power switch before plugging in the unit or performing any maintenance on it. Some installations have more than one disconnect switch. Check for all of them before beginning work.

Broken Lamp Hazard

Never touch a broken UV lamp with bare hands.

UV lamps contain a small amount of mercury and may be harmful to skin and eyes if released. If mercury contacts skin, wash the area immediately with mild soap and water and seek medical attention if necessary. Carefully collect broken pieces and dispose of them in accordance with local environmental regulations.

What is in the Box

Ballast & 2 Bulbs
A

Ballast & 2 Bulbs

Germicidal UV-C bulb

120v Adaptor
B

120v Adaptor

Wall adapter (WallPlug) or external ballast (HVAC)

Air Seal Straps
C

Air Seal Straps

Wall adapter (WallPlug) or external ballast (HVAC)

Metal Drill Bits & Screws
D

Metal Drill Bits & Screws

4-pin keyed connector cable

User Guide
E

User Guide

Threaded strain relief for duct wall (1″ hole)

Installation Template
F

Installation Template

Creates 1″ cable hole (all models) & ½″ sight glass hole (HVAC)

Safety Precautions Before Installing

Turn off HVAC system

Turn off HVAC system and ensure all electrical connections are off.

Wear protective eyewear and gloves

Never look directly at UV-C light. Wear protective eyewear and gloves. Avoid touching the bulb glass or clean it with isopropyl alcohol if touched.

Part 1: Preparing HVAC Wall

01

Position Template

Position template

Place the mounting template on the HVAC panel (included in the kit). It is a sticker and should stick on easily.

02

Drill Holes for Bulbs

Drill holes for bulbs

Drill two holes at the template’s marked positions where the bulbs would go (circular drill bit included).

03

Drill Holes for Mounting Screws

Drill holes for mounting screws

Drill 4 holes on the corners (marked in the template) where the mounting screws would be inserted (circular drill bit included).

Part 2: Preparing Base Unit For Install

01

Slide UV-C Bulbs Into Slots

Slide UV-C bulbs into slots

There are two slots on the base unit. Slide the UV-C bulbs into each slot till you hear them click.

02

Seal Strips (Optional)

Seal strips

Peel off the back of the air-seal strips and stick them around the perimeter of the base unit. (Air-seal strips included in the kit, cut to size if required).

Part 3: Placing Base Unit Onto HVAC Wall

01

Place Unit Into The HVAC Wall

Place unit into the HVAC wall

Pick up the prepared base unit and carefully insert the bulbs into the drilled holes. Make sure the corner holes align with holes on the unit.

02

Screw In

Screw in

Use the provided screws to secure the unit in place.

03

Combine Power

Combine power

Attach the adapter to the base unit, then plug it into a nearby 120 V outlet.

Post-Installation Checks

Ensure the indicator light is ON — this confirms the lamp is operating.

Clean around the unit of any dust to maintain optimal UV performance.

Maintenance & Replacement

Bulbs last approximately 8,000 hours (~1 year of continuous use).

Replace bulbs promptly when the indicator light signals it’s time.

Never Miss a Replacement with Guardian Club

Guardian Club automatically ships you a replacement lamp every 10 months. Members receive 10% off replacement bulbs, automatic warranty coverage, and hassle-free delivery every cycle.

All replacement bulbs include a 14-day warranty from the date of delivery. Guardian Club members receive extended coverage of up to 6 months from delivery.

Free to join. Ships automatically. Keeps your warranty active.

Guardian Club replacement service www.BioShieldUV.com/club

UV-C Lamp Disposal

UV-C lamps contain a small amount of mercury and must be disposed of in accordance with local environmental regulations. Do not place used lamps in standard household waste unless your local waste management authority explicitly permits it.

Visit www.lamprecycle.org to find mercury lamp recycling locations near you, or www.earth911.com to locate your local or state waste management program.

Many hardware and home improvement retailers that sell UV or fluorescent bulbs also accept used bulbs for drop-off recycling at no charge. If no recycling option is available and local regulations allow, seal the lamp in a plastic bag before placing it in household waste collection.

UV-C lamp disposal

Frequently Asked Questions

Do I need a professional installer?
WallPlug models are designed for homeowner installation and require no licensed technician or dedicated wiring. HVAC models connect directly to a 24VAC transformer and must be installed by a licensed HVAC technician or electrician. Installation by an unlicensed individual on an HVAC model voids the warranty.
Where exactly should I install the UV lamp?
On the supply side, downstream of the coil, with a clear line of sight to the coil face and drain pan. See the placement table in Part 1 for your specific airflow orientation.
The lamp has a visible blue glow. Is UV-C actually working?
Check the sight glass (HVAC models) or the external LED (WallPlug models). If there is no light at all, verify power and that all connectors are locked. See Troubleshooting.
Can I wire the unit to run only when the HVAC fan runs?
HVAC models are wired to the blower circuit so the lamp runs whenever the fan runs. WallPlug models run continuously from a standard receptacle.
My unit is showing a red light. What do I do?
A red indicator means the lamp is at or near end of life. Replace it with a genuine TruBlu™ lamp to restore full UV-C output.
Will UV-C damage plastic or rubber components inside my system?
Prolonged direct exposure can degrade some plastics and rubber. Keep non-metallic parts out of the direct beam and inspect nearby materials periodically.
Can I install this on non-metallic ductwork?
Yes. Use the included self-tapping screws to mount the bracket mechanically instead of relying on the magnet. See the Non-Magnetic Surface Alternative.
What if my HVAC is a communicating system such as Nest or Ecobee?
Yes. The unit taps line voltage on the blower circuit and does not communicate with the thermostat, so it works alongside any smart or communicating system.
The unit smells strange on first use. Is that normal?
A faint ozone smell can occur when UV-C first energizes. It should fade quickly. Ventilate the space; a persistent strong smell warrants a check of placement and output.
How do I know when to replace the bulb?
Every 10 months (about 8,000 hours). UV-C output fades before the lamp goes dark, so replace on schedule. The Guardian Club ships replacements automatically.